Planning examples
Server rooms

01 Planning example: IT Compact Server room – PS40

Series: PS40

Features:

  • 5 rack, width 660 mm, 1 reserve space
  • 1 UPS 10kVA
  • PS40 power supply 19″ inch
  • IT cooler above rack 2×7.1kW
  • Rack height 46U

02 Planning example: IT Compact Server room – PS40

Series: PS40

Features:

    • 7 LAN Rack width 660mm
    • Rack height 46 U
    • IT cooler above rack 2×12.5kW, option +1
    • PS40 power supply 19″ inch, pre-safe. 80A
    • PS-E fault alarm and monitoring system
    • Server room without raised floor
    • Ceiling height 2930mm

03 Planning example: IT Compact Server room – PS40

Series: PS40

Features:

  • Cooling via cold water on site
  • Supply/exhaust air UPS room on site
  • Raised floor on site

04 Planning example: IT Compact Server room – Variant 1

Series: PS60

Features:

  • 2 x 7 Rack, width 660 mm
  • 4 x UPS xxkVA
  • PS60 power supply 19″ inch
  • IT cooler above rack 3 x 20kW
  • Room height 370/4150mm (test)
  • Rack cold aisle with lid bulkhead

05 Planning example: IT Compact Server room – Variant 2

Seried: PS80

Features:

  • 2 x 5 rack, width 660 mm
  • 4 x UPS xxkVA
  • PS60 power supply 19″ inch
  • IT cooler above the rack 4 x 20kW
  • Room height 370/4150mm (test)
  • Rack cold aisle with lid bulkhead

06 Planning example: IT Compact Server room – PS100

Series: PS100

Features:

  • 18 rack width 660 mm / option + 10 rack
  • 1 UPS 40kVA (opt. + 3)
  • PS100 power supply 19″ inch
  • IT cooler above rack 3 x 25kW (op. + 4.)
  • Rack height 46U

07 Planning example: IT compact Data center – PS100

Series: PS100

Features:

  • Rack width 660 mm
  • Integration existing rack
  • PS power supply 19″ inch
  • PS-E monitoring system
  • Rack height 46U

08 Planning example: IT compact Data center – PS200

Series: PS200

Features:

  • 40 Rack, option+4, 46U, width 660 mm depth 1000mm
  • PS200 power supply system
  • PS-E monitoring supervision (master-slave)
  • Hot/cold aisle and PS system with ESG glass doors
  • Opening access doors via on-site RFID profile cylinder
  • UPS up to 6 x MST40, 40kVA
  • Cooling up to 35KW per unit
  • Grid partitions variably producible
  • Neutral climate zone outside the rack compartments
  • Possibility of expansion with approx. 16 racks
  • Compact server rooms with intelligent construction technology

  • A safe place for your central IT

  • Planning, realisation, modernisation, expansion

… and we’ll talk about your needs-based solution!